Thursday 30 November 2017

MEGACLI Commands to check Hardware RAID config and Setup

To know the Hardware RAID controller and other information use lspci command.
lspci | grep -i raid
O/P:
01:00.0 RAID bus controller: LSI Logic / Symbios Logic MegaRAID SAS 2108 [Liberator] (rev 05)
The above command shows the RAID controller vendor details.
Installation of Megacli in Centos:
RAID commands:
MegaCli64 commands are formed as given below:
MegaCli64 –command –arguments/directives -a adapter info
View information about the RAID adapter:
/opt/MegaRAID/MegaCli/MegaCli64 -AdpAllinfo -aALL
Results:
Adapter #0
Versions
  • Product Name : LSI MegaRAID SAS 9260-8i
  • Serial No : SV31519225
  • FW Package Build: 12.12.0-0111
Mfg. Data
  • Mfg. Date : 04/10/13
  • Rework Date : 00/00/00
  • Revision No : 85B
  • Battery FRU : N/A
Image Versions in Flash:
  • FW Version : 2.130.353-1663
  • BIOS Version : 3.24.00_4.12.05.00_0x05160000
  • Preboot CLI Version: 04.04-020:#009
  • WebBIOS Version : 6.0-49-e_45-Rel
  • NVDATA Version : 2.09.03-0032
  • Boot Block Version : 2.02.00.00-0000
  • BOOT Version : 09.250.01.219
To Know information in PDrives:
/opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL
Output:
  • Adapter #0
  • Enclosure Device ID: 252
  • Slot Number: 0
  • Drive’s position: DiskGroup: 0, Span: 0, Arm: 0
  • Enclosure position: N/A
  • Device Id: 10
  • WWN: 5000c5005c34c105
  • Sequence Number: 2
  • Media Error Count: 0
  • Other Error Count: 0
  • Predictive Failure Count: 0
  • Last Predictive Failure Event Seq Number: 0
  • PD Type: SATA
To know the PATROL read which explore disk error and the patrol read state and the delay between patrol read runs:
/opt/MegaRAID/MegaCli/MegaCli64 -AdpPR -Info -aALL
Output:
  • Adapter 0: Patrol Read Information:
  • Patrol Read Mode: Auto
  • Patrol Read Execution Delay: 168 hours
  • Number of iterations completed: 78
  • Next start time: 05/02/2015, 03:00:00
  • Current State: Stopped
  • Patrol Read on SSD Devices: Disabled
To check Current patrol read rate:
/opt/MegaRAID/MegaCli/MegaCli64 -AdpGetProp PatrolReadRate -aALL
Adapter 0: Patrol Read Rate = 30%
Get the Number of Virtual Drives Configured on Each Adapter
/opt/MegaRAID/MegaCli/MegaCli64 -LdGetNum -aAll
Number of Virtual Drives Configured on Adapter 0: 2
To know Battery backup information
/opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -aALL
BBU status for Adapter: 0
  • BatteryType: iBBU
  • Voltage: 4085 mV
  • Current: 0 mA
  • Temperature: 29 C
  • Battery State: Optimal
  • BBU Firmware Status:
Display configuration:
/opt/MegaRAID/MegaCli/MegaCli64 -CfgDsply -aAll
  • Adapter: 0
  • Product Name: LSI MegaRAID SAS 9260-8i
  • Memory: 512MB
  • BBU: Present
  • Serial No: SV31519225
Number of DISK GROUPS: 2
  • SPANNED DISK GROUP: 0
  • Number of Spans: 2
  • SPAN: 0
  • Span Reference: 0x00
  • Number of PDs: 2
  • Number of VDs: 1
  • Number of dedicated Hotspares: 0
  • Virtual Drive Information:
  • Virtual Drive: 0 (Target Id: 0)
Enable Forced Write Back Cache:
/opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp -ForcedWB -Immediate -Lall -aAll
To disable cache with a bad BBU with MegaCLI
/opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp -NoCachedBadBBU -Immediate -Lall -aAll
To Enable Drive Caches with MegaCLI
/opt/MegaRAID/MegaCli/MegaCli64 -LDSetProp -EnDskCache -Immediate -Lall -aAll

No comments: